Parameters List 37
31.12 Auto-reset selection 0x0000…0xffff - 0x0000
31.13 Selectable fault 0x0000…0xffff - 0x0000
31.14 Number of trials 0…5 - 0
31.15 Total trials time 1.0...600.0 s 30.0
31.16 Delay time 0.0...120.0 s 0.0
31.19 Motor phase loss No action[0], Fault[1] - Fault[1]
31.20 Earth fault No action[0], Warning[1],
Fault[2]
- Fault[2]
31.21 Supply phase loss No action[0], Fault[1] - Fault[1]
31.22 STO indication run/stop
0...5 -
Fault/Fault
[0]
31.23 Wiring or earth fault No action[0], Fault[1] - Fault[1]
31.24 Stall function No action[0], Warning[1],
Fault[2]
- Fault[2]
31.25 Stall current limit 0.0...1600.0 % 200.0
31.26 Stall speed limit 0.00...10000.00 rpm 150.00
31.27 Stall frequency limit 0.00...1000.00 Hz 10.00
31.28 Stall time 0…3600 s 10
31.30 Over-speed trip margin 0.00...10000.00 rpm 2000.00
31.31 Frequency trip margin 0.00...10000.00 Hz 15.00
32 Supervision
32.01 Supervision status 0b0000…0b1111 - 0b0000
32.05 Supervision 1 function 0...7 - Disabled[0]
32.06 Supervision 1 action No action[0], Warning[1],
Fault[2], Fault if running[3]
- No action[0]
Index Name Range/List Unit Default
Bit Value Bit Value Bit Value
0 Overcurrent 4…9 Reserved 13 External fault 3
1 Overvoltage 10 Selectable fault 14 External fault 4
2 Undervoltage 11 External fault 1 15 External fault 5
3 AI supervision fault 12 External fault 2
Fault/Fault[0]
Fault/Event[2] Event/Event[4]
Fault/Warning[1]
Warning/Warning[3] No indication/No indication[5]
Bit Name Bit Name Bit Name
0 Supervision 1 active 3 Supervision 4 active 6…15 Reserved
1 Supervision 2 active 4 Supervision 5 active
2 Supervision 3 active 5 Supervision 6 active
Disabled[0] High[2] Abs high[4] Abs both[6]
Low[1] Abs low[3] Both[5] Hysteresis[7]
ACQ80R0-R8 QIG.book Page 37 Friday, February 1, 2019 1:18 PM