36 Parameters List
EN
ES
FI
FR
IT
PL
PT
RU
SV
TR
ZH
30.09 Cur Lim Monitor Time 0.00...120.00 s 10.00
30.10 Current Limit Actions No Action[0], Warning[1],
Fault[2]
- Warning[1]
30.11 Minimum speed -30000.00...30000.00 rpm -3000.00
30.12 Maximum speed -30000.00...30000.00 rpm 3000.00
30.13 Minimum frequency -500.00...500.00 Hz -50.00
30.14 Maximum frequency -500.00...500.00 Hz 50.00
30.17 Maximum current 0.00...3.24 A 3.24
30.19 Minimum torque 1 -1600.0...0.0 % -300.0
30.20 Maximum torque 1 0.0...1600.0 % 300.0
30.31 Undervoltage control Disable[0], Enable[1] - Enable[1]
30.35 Thermal current limitation Disable[0], Enable[1] Enable[1]
30.36 Speed limit selection
0...8
Not
selected[0]
30.37 Min speed source
-
Minimum
speed[11]
30.38 Min speed source
-
Minimum
speed[11]
31 Fault functions
31.01 External event 1 source
0, 1, 3...8 -
Inactive
(true)[1]
31.02 External event 1 type Fault[0], Warning[1] - Fault[0]
31.03 External event 2 source See parameter 31.01 External
event 1 source
-
Inactive
(true)[1]
31.04 External event 2 type Fault[0], Warning[1] - Fault[0]
31.05 External event 3 source See parameter 31.01 External
event 1 source
-
Inactive
(true)[1]
31.06 External event 3 type Fault[0], Warning[1] - Fault[0]
31.07 External event 4 source See parameter 31.01 External
event 1 source
-
Inactive
(true)[1]
31.08 External event 4 type Fault[0], Warning[1] - Fault[0]
31.09 External event 5 source See parameter 31.01 External
event 1 source
-
Inactive
(true)[1]
31.10 External event 5 type Fault[0], Warning[1] - Fault[0]
31.11 Fault reset selection
0...7, 18...20, 24...26 -
Not
selected[0]
Index Name Range/List Unit Default
Not selected[0] Ext1 active[2] Torque control[4]
DI2[6]
DI4[8]
Selected[1] Ext2 active[3] DI1[5] DI3[7] Other...
Zero[0] AI1 scaled[1] AI2 scaled[2] Minimum speed[11] Other...
Zero[0] AI1 scaled[1] AI2 scaled[2] Maximum speed[11] Other...
Active (false)[0] Inactive (true)[1] DI1[3] DI2[4] DI3[5] DI4[6] DI5[7] DI6[8]
Not selected[0] DI2[3] DI5[6]
Timed function 2[19] -
Not applicable.
Supervision 2[25]
Selected[1]
DI3[4] DI6[7]
Timed function 3[20] -
Not applicable.
Supervision 3[26]
DI1[2]
DI4[5]
Timed function [18] -
Not applicable.
Supervision 1[24] Other...
ACQ80R0-R8 QIG.book Page 36 Friday, February 1, 2019 1:18 PM