Technical data 53
Technical data
What this chapter contains
This chapter contains the following technical specifications of the drive:
Ratings
Specifications See page...
Ratings 53
Fuses 54
Note: For DC power cable specifications are based on the PV manufacturer 57
Standard frame sizes (R0...R8) 58
Drive Type
ACQ80-04
Nominal
In
DC Input
current
Max.
current
Output ratings Frame
size
Nominal use
I
1N
A
I
max
I
N
P
N
A A A kW Hp
3 phases U
N
= 400 V (380…480 V)
0kW75-4 2.6 2.12 3.2 2.6 0.75 1 R0
01kW1-4 3.3 2.7 4.7 3.3 1.1 1.5 R0
01kW5-4 4 3.27 5.9 4 1.5 2 R0
02kW2-4 5.6 4.58 7.2 5.6 2.2 3 R0
03kW0-4 7.2 5.88 10.1 7.2 3 4 R0
04kW0-4 9.4 7.68 13 9.4 4 5 R0
05kW5-4 12.6 10.29 16.9 12.6 5.5 7.5 R1
07kW5-4 17 13.89 22.7 17 7.5 10 R2
011kW-4 25 20.43 30.6 25 11 15 R2
015kW-4 33 26.96 44.3 33 15 20 R3
18kW5-4 39 31.86 56.9 39 18.5 25 R3
022kW-4 46 37.58 67.9 46 22 30 R3
030kW-4 62 50.65 76 62 30 40 R4
037kW-4 73 59.64 104 73 37 50 R4
045kW-4 88 71.9 122 88 45 60 R5
055kW-4 106 86.60 148 106 55 75 R5
075kW-4
1)
145 118.47 178 145 75 100 R6
090kW-4
1)
169 138.07 247 169 90 120 R7
110kW-4
1)
206 168.30 287 206 110 150 R7
132kW-1
1)
246 200.98 350 246 132 180 R8
160kW-4
1)
293 239.38 418 293 160 215 R8
1)
External charging circuit required. For details on charging unit, contact your local ABB representative.