96.101 Confirm user pass code 10000000…99999999 - -
96.102 User lock functionality 0000h…FFFFh - 0000h
97 Motor control
97.01 Switching frequency reference 2 kHz[2], 4 kHz[4], 8 kHz[8],
16 kHz[16]
- 4 kHz[4]
97.02 Minimum switching frequency 1, 2, 4, 8, 12 - 1.5 kHz[1]
97.13 IR compensation 0.00...50.00 % 3.50
97.20 U/F ratio Linear[0], Squared[20] - Linear[0]
97.49 Slip gain for scalar 0...200 % 0
97.94 IR comp max frequency 1.0...200.0 % 50.0
98 User motor parameters
98.01
User motor model mode
Not selected[0], Motor
parameters[1]
-
Not
selected[0]
98.02 Rs user 0.00000…0.50000 p.u. 0.00000 p.u
98.03 Rr user 0.00000…0.50000 p.u. 0.00000 p.u
98.04 Lm user 0.00000…10.00000 p.u. 0.00000 p.u
98.05 SigmaL user 0.00000…1.00000 p.u. 0.00000 p.u
98.06 Ld user
0.00000…10.00000 p.u.
100000 = 1
p.u.
98.07 Lq user
0.00000…10.00000 p.u.
100000 = 1
p.u.
98.08 PM flux user
0.00000…2.00000 p.u.
100000 = 1
p.u.
98.09 Rs user SI 0.00000…100.00000 ohm 0.00000 ohm
98.10 Rr user SI 0.00000…100.00000 ohm 0.00000 ohm
98.11 Lm user SI 0.00…100000.00 mH 0.00 mH
98.12 SigmaL user SI 0.00…100000.00 mH 0.00 mH
98.13 Ld user SI 0.00…100000.00 mH 0.00
98.14 Lq user SI 0.00…100000.00 mH 0.00
99 Motor data
99.03 Motor type Asynchronous motor[0],
Permanent magnet motor[1]
-
Asynchronous
motor[0]
99.04 Motor control mode Vector[0], Scalar[1] - Scalar[1]
99.06 Motor nominal current 0.0...5.2 A 1.8
99.07 Motor nominal voltage 69.2...830.0 V 400.0
99.08 Motor nominal frequency 0.00…500.00 Hz 50.00
99.09 Motor nominal speed 0…30000 rpm 1430
99.10 Motor nominal power 0...10,000 kW or hp 0.75
99.11 Motor nominal cos? 0.00 1.00 - 0.00
99.12 Motor nominal torque 0.000…4000000.000 N·m or
0.000…2950248.597 lb·ft
N·m 0.000
99.13 ID run requested 0...3, 5, 6 - None[0]
99.14 Last ID run performed See parameter 99.13 ID run
requested
- None[0]
Index Name Range/List Unit Default
1.5 kHz[1] 2 kHz[2] 4 kHz[4] 8 kHz[8] 12 kHz[12]
None[0] Reduced[2] Autophasing[4] Advanced[6]
Normal[1] Standstill[3] Current measurement calibration[5] Adaptive[7]
Note: Adaptive ID run is applicable for R0...R5 frames and Advanced ID run is applicable for
R6...R8 frames.
ACQ80R0-R8 QIG.book Page 50 Friday, February 1, 2019 1:18 PM

Other manuals for ABB ACQ80-04

Related product manuals