Parameters List 41
EN
TR
ZH
40.07 Set 1 PID operation mode 0...2 - Off[0]
40.08 Set 1 feedback 1 source 0...3, 8...10 - AI2 percent[9]
40.11 Set 1 feedback filter time 0.000...30.000 s 0.000
40.14 Set 1 setpoint scaling -200000.00...200000.00 - 100.00
40.15 Set 1 output scaling -200000.00...200000.00 - 100.00
40.16 Set 1 setpoint 1 source
0, 2...4, 8, 10...16, 19, 20, 24 -
AI1
percent[11]
40.24 Set 1 internal setpoint 0 -200000.00...200000.00 PID unit 1 0.00
40.26 Set 1 setpoint min -200000.00...200000.00 PID unit 1 0.00
40.27 Set 1 setpoint Max -200000.00...200000.00 PID unit 1 200000.00
40.28 Set 1 setpoint increase time 0.0...1800.0 s 0.0
40.29 Set 1 setpoint decrease time 0.0...1800.0 s 0.0
40.30 Set 1 setpoint freeze enable
0...7, 21...23 -
Not
selected[0]
40.31 Set 1 deviation inversion Not inverted (Ref - Fbk)[0],
Inverted (Fbk - Ref)[1]
-
Not inverted
(Ref - Fbk)[0]
40.32 Set 1 gain 0.01...100.00 - 1.00
40.33 Set 1 integration time 0.0...9999.0 s 60.0
40.34 Set 1 derivation time 0.0…10.000 s 0.000
40.35 Set 1 derivation filter time 0.0...10.0 s 0.0
40.36 Set 1 output min -100.00...100.00 - 0.00
40.37 Set 1 output max -100.00...100.00 - 100.00
40.38 Set 1 output freeze enable See parameter 40.30 Set 1
setpoint freeze enable
-
Not
selected[0]
40.39 Set 1 deadband range 0.0...200000.00 - 0.0
40.40 Set 1 deadband delay 0.0...3600.0 s 0.0
40.43 Set 1 sleep level 0.0...200000.00 - 0.0
Index Name Range/List Unit Default
Bit Name Bit Name Bit Name Bit Name Bit Name
0 PID active 3
PID sleep
mode
6
Tracking
mode
9Reserved12
Internal
setpoint
active
1
Setpoint
frozen
4 Sleep boost 7
Output limit
high
10 PID set 13...15 Reserved
2 Output frozen 5 Reserved 8
Output limit
low
11 Reserved
Off[0] On[1] On when drive running[2]
Not selected[0] Freq in scaled[3] Feedback data storage[10]
AI1 scaled[1] AI1 percent[8] .Actual flow[11]
AI2 scaled[2] AI2 percent[9] Other...
Not selected[0]
Motor potentiometer[8] -
Not applicable.
Control panel (ref
saved)[13]
EFB ref1[19]
Internal setpoint[2] Freq in scaled[10]
Control panel (ref
copied)[14]
EFB ref2[20]
AI1 scaled[3] AI1 percent[11] FB A ref1[15] Setpoint data storage[24]
AI2 scaled[4] AI2 percent[12] FB A ref2[16] Other...
Not selected[0] DI2[3] DI5[6] Supervision 2[22]
Selected[1]
DI3[4] DI6[7] Supervision 3[23]
DI1[2]
DI4[5] Supervision 1[21] Other...
ACQ80R0-R8 QIG.book Page 41 Friday, February 1, 2019 1:18 PM