NPN configuration for digital inputs
Internal and external +24 V power supply connections for NPN (sink) configuration are
shown in the figures below.
WARNING!
If you connect DIO1 or DIO2 as shown in the figures below, make sure that they
are configured as inputs. If they are configured as outputs, it can cause damage
to the equipment.
External +24 V power supplyInternal +24 V power supply
0 V DC
+24 V DC
DI1
DI2
DI3
DI4
DIO1
DIO2
+24 V
DGND
DCOM
DI1
DI2
DI3
DI4
DIO1
DIO2
+24 V
DGND
DCOM
Connection examples of two-wire and three-wire sensors
The figures give examples of connections for a two-wire or three-wire sensor/transmitter
that is supplied by the auxiliary voltage output of the drive.
P
I
-
+
4…20 mA
AI2
AGND
+24V
DGND
Process actual value measurement or reference, 0(4) 20 mA, R
in
= 137 ohm. If the
sensor power supply comes through its current output circuit, use 4 20 mA signal,
not 0 20 mA.
AI2
AGND
Auxiliary voltage output, non-isolated, +24 V DC, max. 250 mA+24V
DGND