EasyManua.ls Logo

ABB ACS880 PCP - Page 118

ABB ACS880 PCP
494 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
118 Parameters
06.17 Drive status word 2 Drive status word 2.
This parameter is read-only.
-
0000h…FFFFh Drive status word 2. 1 = 1
No. Name/Value Description Def/
FbEq16
Bit Name Description
0 Identification run
done
1 = Motor identification (ID) run has been performed
1 Magnetized 1 = The motor has been magnetized
2 Torque control 1 = Torque control mode active
3 Speed control 1 = Speed control mode active
4 Power control 1 = Power control mode active
5 Safe reference
active
1 = A “safe” reference is being applied by functions such
as parameters 49.05 and 50.02
6 Last speed active 1 = A “last speed” reference is being applied by functions
such as parameters 49.05 and 50.02
7 Loss of reference 1 = Reference signal lost
8 Emergency stop
failed
1 = Emergency stop failed (see parameters 31.32 and
31.33)
9 Jogging active 1 = Jogging enable signal is on
10 Above limit 1 = Actual speed, frequency or torque equals or exceeds
limit (defined by parameters 46.31…46.33). Valid in both
directions of rotation.
11 Emergency stop
active
1 = An emergency stop command signal is active, or the
drive is stopping after receiving an emergency stop
command.
12 Reduced run 1 = Reduced run active (see section See parameter group
47 Data storage (page 281). on page 92)
13 Reserved
14 Stop failed 1 = Stopping failed (see parameter 31.37 and 31.38.
15 Reserved

Table of Contents