154 Parameters
14.20 AI supervision
selection
(Visible when 14.01 Module 1 type = FIO-11 or FAIO-01)
Specifies the analog input limits to be supervised. See
parameter 14.19 AI supervision function.
Note: The number of active bits in this parameters
depends on the number of inputs on the extension module.
0000 0000b
0000 0000b…0011
1111b
Activation of analog input supervision. 1 = 1
14.21 DIO3 output source (Visible when 14.01 Module 1 type = FIO-01)
Selects a drive signal to be connected to digital
input/output DIO3 when parameter 14.19 DIO3 function is
set to Output.
For the available selections, see parameter 14.11 DIO1
output source.
Not energized
14.21 AI tune (Visible when 14.01 Module 1 type = FIO-01 or FAIO-01)
Triggers the analog input tuning function, which enables
the use of actual measurements as the minimum and
maximum input values instead of potentially inaccurate
estimates.
Apply the minimum or maximum signal to the input and
select the appropriate tuning function.
See also the drawing at parameter 14.35 AI1 scaled at AI1
min.
No action
No action Tuning action completed or no action has been requested.
The parameter automatically reverts to this value after any
tuning action.
0
AI1 min tune The measured value of AI1 is set as the minimum value of
AI1 into parameter 14.33 AI1 min.
1
AI1 max tune The measured value of AI1 is set as the maximum value of
AI1 into parameter 14.34 AI1 max.
2
AI2 min tune The measured value of AI2 is set as the minimum value of
AI2 into parameter 14.48 AI2 min.
3
AI2 max tune The measured value of AI2 is set as the maximum value of
AI2 into parameter 14.49 AI2 max
.
4
AI3 min tune (Visible when 14.01 Module 1 type = FIO-11)
The measured value of AI3 is set as the minimum value of
AI3 into parameter 14.63 AI3 min.
5
AI3 max tune (Visible when 14.01 Module 1 type = FIO-11)
The measured value of AI3 is set as the maximum value of
AI3 into parameter 14.64 AI3 max.
6
No. Name/Value Description Def/
FbEq16
Bit Name Description
0 AI1 < MIN 1 = Minimum limit supervision of AI1 active.
1 AI1 > MAX 1 = Maximum limit supervision of AI1 active.
2 AI2 < MIN 1 = Minimum limit supervision of AI2 active.
3 AI2 > MAX 1 = Maximum limit supervision of AI2 active.
4 AI3 < MIN 1 = Minimum limit supervision of AI3 active (FIO-11 only).
5 AI3 > MAX 1 = Maximum limit supervision of AI3 active (FIO-11 only).
6…15 Reserved