274 Parameters
36.13 PVL current at peak Displays the motor current at the moment the peak value
was recorded.
0.00 A
-32768.00
…32767.00 A
Motor current at peak. 1 = 1 A
36.14 PVL DC voltage at
peak
Displays the voltage in the intermediate DC circuit of the
drive at the moment the peak value was recorded.
0.00 V
0.00…2000.00 V DC voltage at peak. 10 = 1 V
36.15 PVL speed at peak Displays the motor speed at the moment the peak value
was recorded.
0.00 rpm
-32768.00
…32767.00 rpm
Motor speed at peak. See par.
46.01
36.16 PVL reset date Displays the date on which the peak value logger was last
reset.
-
- Last reset date of the peak value logger. -
36.17 PVL reset time Displays the time at which the peak value logger was last
reset.
-
- Last reset time of the peak value logger. -
36.20 AL1 0 to 10% Displays the percentage of samples recorded by amplitude
logger 1 that fall between 0 and 10%.
0.00%
0.00…100.00% Amplitude logger 1 samples between 0 and 10%. 1 = 1%
36.21 AL1 10 to 20% Displays the percentage of samples recorded by amplitude
logger 1 that fall between 10 and 20%.
0.00%
0.00…100.00% Amplitude logger 1 samples between 10 and 20%. 1 = 1%
36.22 AL1 20 to 30% Displays the percentage of samples recorded by amplitude
logger 1 that fall between 20 and 30%.
0.00%
0.00…100.00% Amplitude logger 1 samples between 20 and 30%. 1 = 1%
36.23 AL1 30 to 40% Displays the percentage of samples recorded by amplitude
logger 1 that fall between 30 and 40%.
0.00%
0.00…100.00% Amplitude logger 1 samples between 30 and 40%. 1 = 1%
36.24 AL1 40 to 50% Displays the percentage of samples recorded by amplitude
logger 1 that fall between 40 and 50%.
0.00%
0.00…100.00% Amplitude logger 1 samples between 40 and 50%. 1 = 1%
36.25 AL1 50 to 60% Displays the percentage of samples recorded by amplitude
logger 1 that fall between 50 and 60%.
0.00%
0.00…100.00% Amplitude logger 1 samples between 50 and 60%. 1 = 1%
36.26 AL1 60 to 70% Displays the percentage of samples recorded by amplitude
logger 1 that fall between 60 and 70%.
0.00%
0.00…100.00% Amplitude logger 1 samples between 60 and 70%. 1 = 1%
36.27 AL1 70 to 80% Displays the percentage of samples recorded by amplitude
logger 1 that fall between 70 and 80%.
0.00%
0.00…100.00% Amplitude logger 1 samples between 70 and 80%. 1 = 1%
36.28 AL1 80 to 90% Displays the percentage of samples recorded by amplitude
logger 1 that fall between 80 and 90%.
0.00%
0.00…100.00% Amplitude logger 1 samples between 80 and 90%. 1 = 1%
No. Name/Value Description Def/
FbEq16