Refitting, SMB unit
The procedure below details how to refit the SMB unit.
NoteAction
xx0600003053
Push the SMB unit into its tracks and secure it
with its hexagon nuts.
1
A : Hexagon nut, M5
B : Tooth lock washer, 6.4 fzb
C : Hexagon screw, M5x12
quality 8.8
xx0600003054
Reconnect the connectors to the SMB unit.
If cabling is used for 7th axis (option), refit the
connector R2.FB7 to the SMB cover and tighten
with 6 Nm.
2
Connector R1.GReconnect the battery cable.3
Make sure the lock on the battery cable connect-
or R1.G snaps into place during refitting.
Shown in the figure Location of SMB
unit on page 233.
Put the SMB/BU unit back into its box and refit
the attachment screws.
4
Detailed in section Updating revolution
counters on page 313.
Update the revolution counters!5
Continues on next page
236 Product manual - IRB 6620
3HAC027151-001 Revision: T
© Copyright 2006-2018 ABB. All rights reserved.
4 Repair
4.5.1 Replacement of SMB unit
Continued