Removing, brake release board
Use this procedure to remove the brake release board.
NoteAction
DANGER
Turn off all:
electric power supply to the robot
hydraulic pressure supply to the robot
air pressure supply to the robot
Before entering the robot working area.
1
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before handling
the unit read the safety information in section
The unit is sensitive to ESD on page 32
2
Remove the cover for the push button guard.3
Shown in the figure Location of brake
release board on page 238.
Remove the push button guard from the SMB
cover.
4
The guard must be removed to ensure
a correct refitting of the brake release
board.
Take a picture or make notes of how the robot
cabling is positioned in regard to the brake
release board.
5
Unscrew the attachment screws of the
SMB/BU unit and carefully lift the unit out of
its box.
6
Let the battery stay connected, to avoid the
need of synchronization of the robot!
CAUTION
Clean cover from metal residues before
opening.
Metal residues can cause shortage on the
boards which can result in hazardous failures.
X9
X8
X10
xx1700000978
Disconnect the connectors X8, X9 and X10
from the brake release board.
7
Location of the brake release unit is
shown in the figure Location of brake
release board on page 238.
Continues on next page
Product manual - IRB 6620 239
3HAC027151-001 Revision: T
© Copyright 2006-2018 ABB. All rights reserved.
4 Repair
4.5.2 Replacing the brake release board
Continued