For most cases after motor and transmission replacements that do not include
taking apart the robot structure, standard calibration is sufficient. Standard
calibration also supports wrist exchange.
References
Article numbers for the calibration tools are listed in the section Special tools on
page 347.
The calibration equipment for Calibration Pendulum is delivered as a complete
toolkit, including the Operating manual - Calibration Pendulum, which describes
the method and the different routines further.
308 Product manual - IRB 6620
3HAC027151-001 Revision: T
© Copyright 2006-2018 ABB. All rights reserved.
5 Calibration
5.1.2 Calibration methods
Continued