Debugger Software (for Microsoft Windows) E-OCD II Debugger Users Manual
32
3.3.9 Emulation : Step Over
The emulation pauses at the next line of code or the next mnemonic code.
3.3.10 Emulation : Step Auto
: It executes a step run every 100ms. You can halt it by clicking the Stop button.
3.3.11 Emulation : Stop
It halts the current emulation or step run immediately.
3.3.12 Emulation : Apply Reset
Target OCD devices have a variety of reset options, as given below:
Power-ON reset
External reset pin input
Watch-dog timer reset
OCD debugger’s command reset
The results of these operations are basically the same: They initialize the target device. This menu
acts as the OCD debugger’s command reset.