MC96F6432
June 22, 2018 Ver. 2.9 179
T4PCR3 (Timer 4 PWM Control Register 3) : 1005H (ESFR)
Initial value : 00H
High-Impedance Output Clear Bit
Clear high-impedance output
(The PWM4xA/PWM4xB pins are back to output and this bit is
automatically cleared to logic ‘0’. where x = A, B and C)
Configure PWM4AB/PWM4BB/PWMCB Channel Polarity When these
pins are disabled
These pins are output according to the polarity setting when
disable (POLAB/POLBB/POLCB bits)
These pins are same level as the PWM4xA pins regardless of
the polarity setting when disable (POLAB/POLBB/POLCB bits,
where x = A, B and C)
Configure PWM4AA Channel Polarity
Start at high level (This pin is low level when disable)
Start at low level (This pin is high level when disable)
Configure PWM4AB Channel Polarity
Non-inversion signal of PWM4AA pin
Inversion signal of PWM4AA pin
Configure PWM4BA Channel Polarity
Start at high level (This pin is low level when disable)
Start at low level (This pin is high level when disable)
Configure PWM4BB Channel Polarity
Non-inversion signal of PWM4BA pin
Inversion signal of PWM4BA pin
Configure PWM4CA Channel Polarity
Start at high level (This pin is low level when disable)
Start at low level (This pin is high level when disable)
Configure PWM4CB Channel Polarity
Non-inversion signal of PWM4CA pin
Inversion signal of PWM4CA pin