6868 69|
15. Technical data
Electromagnetic compatibility
EMC – immunity
Complies with EN 50130-4
Electromagnetic compatibility
EMC – interference
Complies with EN 61000-6-3
Electrical safety
Complies with EN60950-1
Power supply
Type of power supply
Type A (EN 50131-1 Section 9 and EN 50131-6 Section 4.1)
Secvest has an integrated power supply unit (Type A). This power supply
unit supplies dierent internal voltages to the circuit board to supply
power to the circuitry.
This power supply unit supplies 13.8V with a maximum of 700mA
atthe 0V/12V AUX output.
Normal voltage/frequency
110V/230VAC, 50/60Hz, (85-265VAC, 50/60Hz)
13.8VDC (13.0–14.5VDC)
Power consumption, maximum
I AC MAX:
430mA rms @ 85VAC
190mA rms @ 230VAC
170mA rms @ 265VAC
Power consumption, nominal
6.9W
6.9W x 24 x 365 = 60kWh per year
55mA rms @ 230VAC
specied with 200mA aux load and fully charged batteries
300mA @ 13.8V
External DC input fault triggered at
12.5V
OK at 12.7V
External PSU
13.0–14.5VDC, at least 1.7A
Power consumption, typical
Alarm panel standby: 100mA
Backlighting o
Backlighting:
High: 100mA
Medium: 40mA
Low: 15mA
Internal siren sounding alarm at maximum volume: 70mA
GSM standby:15mA
GSM in use: 140mA
Battery charging current per battery: 220mA