15. Technical data
Backup power supply
Rechargeable battery
Polymer lithium ion, 7.4V
Capacity
2500mAh, 18.5Wh
Minimum running time in
emergency power mode
(standby time)
More than 12 hours
More than 24hours with optional second battery
Maximum recharging time
Less than 72 hours (EN 50131-1 Section 9 Table 24)
Maximum time to recharge
the battery to 80%
24 hours)
Lower threshold value
of the battery
7.2V
"Flat battery" fault at <7.2V
Deep discharge protection at
6 +/- 0.2V
Aux power supply output
Running on the mains (85–265VAC, 50/60Hz)
13.9Vmax, idle
13.4Vmin, full load (@ 700 mA)
Running on DC input
@13.0V
12.8V max, idle
12.2V min, full load (@ 700mA)
@13.8V
13.6V max, idle
13.0V min, full load (@ 700mA)
@14.5V
14.3V max, idle
13.7V min, full load (@ 700mA)
Aux power supply output fault
triggered at
11.5V
OK from 12.0V
Surge protection
trip voltage
Not given for grade 2
PSU monitoring
Monitoring covers AC and external DC faults.
It noties the alarm panel if the AC or external DC power supply
isdisrupted or fails. The alarm panel will continue running on
thebatteries but the alarm panel and user are informed.
Monitoring covers battery under voltage.
If the battery is at, the alarm panel and user are informed and
thealarm panel gives a warning.