EVO 150 Controller
30
5 2 1 4
Same function as option 13, except the polarity of the AUXILIARY input
is inverted.
Note: If your application requires a non-isolated AUXILIARY input, then set parameter 72 to 1.
Parameters 53 and 54 are reserved for future use.
Sensor A Type
5 5 0
Sensor A is an ultrasonic edge detector. This is the default setting.
5 5 1
Sensor A is an IR edge detector.
Note: This value is set by the Setting Screen Edge Detector Settings button.
Sensor B Type
5 6 0
Sensor B is an ultrasonic edge detector. This is the default setting.
5 6 1
Sensor B is an IR edge detector.
Note: This value is set by the Setting Screen Edge Detector Settings button.
Parameters 57 through 61 are reserved for future use.
Manual Polarity
6 2 0
The actuator extends when the In mode is selected, and retracts when
the Out mode is selected.
6 2 1
The actuator extends when the Out mode is selected, and retracts when
the In mode is selected. This is the default setting.