Appendix B 115
SCPI Command Reference
:CALC{1-4}:TRAN:DIST:IMP:WIDT
:CALC{1-4}:TRAN:DIST:IMP:WIDT
Syntax :CALCulate{[1]|2|3|4}[:SELected]:TRANsform:DISTance:IMPulse:WIDTh <numeric>
:CALCulate{[1]|2|3|4}[:SELected]:TRANsform:DISTance:IMPulse:WIDTh?
Description For the active trace of channel 1 (:CALC1) to channel 4 (:CALC4), sets the shape of the
Kayser Bessel window using the impulse width used for the transformation function of the
fault location function.
Parameters
If the specified parameter is out of the allowable setup range, the minimum value (if the
lower limit of the range is not reached) or the maximum value (if the upper limit of the
range is exceeded) is set.
Query response {numeric}<newline><^END>
Example of use 10 OUTPUT 717;":CALC1:TRAN:TIME:IMP:WIDT 1E-10"
20 OUTPUT 717;":CALC1:TRAN:TIME:IMP:WIDT?"
30 ENTER 717;A
Related commands :CALC{1-4}:TRAN:TIME:IMP:WIDT on page 130
:CALC{1-4}:TRAN:DIST:KBES on page 116
:CALC{1-4}:TRAN:DIST:STEP:RTIM on page 122
:CALC{1-4}:TRAN:DIST:STAT on page 121
Equivalent key [Analysis] - Fault Location - Window - Impulse Width
<numeric>
Description Impulse width
Range Varies depending on the frequency span and the transformation
type.
Preset value Varies depending on the frequency span and the transformation
type.
Unit s (second)