Appendix B 119
SCPI Command Reference
:CALC{1-4}:TRAN:DIST:SPAN
:CALC{1-4}:TRAN:DIST:SPAN
Syntax :CALCulate{[1]|2|3|4}[:SELected]:TRANsform:DISTance:SPAN <numeric>
:CALCulate{[1]|2|3|4}[:SELected]:TRANsform:DISTance:SPAN?
Description For the active trace of channel 1 (:CALC1) to channel 4 (:CALC4), sets the span value of
the fault location display.
Parameters
If the specified parameter is out of the allowable setup range, the minimum value (if the
lower limit of the range is not reached) or the maximum value (if the upper limit of the
range is exceeded) is set.
Query response {numeric}<newline><^END>
Example of use 10 OUTPUT 717;":CALC1:TRAN:DIST:SPAN 1E-8"
20 OUTPUT 717;":CALC1:TRAN:DIST:SPAN?"
30 ENTER 717;A
Related commands :CALC{1-4}:TRAN:DIST:CENT on page 113
:CALC{1-4}:TRAN:DIST:STAT on page 121
Equivalent key [Analysis] - Fault Location - Span
<numeric>
Description Span value
Range Varies depending on the frequency span, velocity factor, distance
unit, and the number of points.
Preset value 19.671 Ft or 5.9958 m
Unit Ft (feet) or m (meters)