Technical Data Upow Units X Type
Performance Data Standard Condenser
TC = Total Cooling
SC = Sensible Cooling
(1) All data quoted is gross
Operating Limits
Indoor Air Temperature +18°C to +28°C
Indoor RH% +40% to +55%
Outdoor Temperature -20°C to +41°C
Cooling Capacity (1) Ambient
Air On
25°C 30°C 35°C 40°C
(DB°C/%RH)
TC (kW) SC (kW) TC (kW) SC (kW) TC (kW) SC (kW) TC (kW) SC (kW)
V6X-EZRE CR12
22/50
6.4 6.3 6.4 6.3 6.4 6.3 6.0 6.0
24/45
6.7 6.7 6.7 6.7 6.6 6.6 6.3 6.3
26/40
7.0 7.0 7.0 7.0 6.9 6.9 6.6 6.6
V8X-EZRE CR16
22/50
8.1 8.1 8.1 8.1 8.1 8.1 7.7 7.7
24/45
8.4 8.4 8.4 8.4 8.4 8.4 8.1 8.1
26/40
8.9 8.9 8.9 8.9 8.9 8.9 8.5 8.5
V10X-EZRE CR16
22/50
10.6 10.6 10.6 10.6 10.5 10.5 9.9 9.9
24/45
11.1 11.1 11.1 11.1 10.9 10.9 10.4 10.4
26/40
11.6 11.6 11.6 11.6 11.4 11.4 10.9 10.9
V13X-EZRE CR22
22/50
13.8 12.8 13.8 12.8 13.6 12.7 12.9 12.2
24/45
14.3 14.1 14.3 14.1 14.1 14.0 13.4 13.4
26/40
14.8 14.8 14.8 14.8 14.6 14.6 13.9 13.9
V15X-EZRE CR22
22/50
15.6 15.0 15.6 15.0 15.3 14.7 14.5 14.2
24/45
16.2 16.2 16.2 16.2 15.8 15.8 15.1 15.1
26/40
16.7 16.7 16.7 16.7 16.4 16.4 15.3 15.3
V17X-EZRE CR30
22/50
18.0 17.1 18.0 17.1 17.8 16.9 16.8 16.3
24/45
18.6 18.6 18.6 18.6 18.3 18.3 17.3 17.3
26/40
19.2 19.2 19.2 19.2 18.8 18.8 17.9 17.9
V20X2-EZRE CR30
22/50
21.6 20.5 21.6 20.5 21.0 20.1 19.8 19.3
24/45
22.5 22.5 22.5 22.5 21.7 21.7 20.6 20.6
26/40
23.4 23.4 23.4 23.4 22.6 22.6 21.5 21.5
V22X2-EZRE CR50
22/50
22.2 21.9 22.2 21.9 22.2 21.9 21.4 21.3
24/45
23.2 23.2 23.2 23.2 23.2 23.2 22.3 22.3
26/40
24.2 24.2 24.2 24.2 24.2 24.2 23.3 23.3
V26X2-EZRE CR50
22/50
27.3 24.9 27.3 24.9 27.3 24.9 25.8 24.0
24/45
28.3 27.3 28.3 27.3 28.2 27.2 26.8 26.2
26/40
29.4 29.4 29.4 29.4 29.3 29.3 27.8 27.8
V28X-EZRE CR50
22/50
26.0 25.6 26.0 25.6 26.0 25.6 24.8 24.6
24/45
27.3 27.3 27.3 27.3 27.3 27.3 26.0 26.0
26/40
28.7 28.7 28.7 28.7 28.6 28.6 27.4 26.9
V28X2-EZRE CR50
22/50
25.9 25.5 25.9 25.5 25.9 25.5 24.6 24.4
24/45
27.1 27.1 27.1 27.1 27.1 27.1 25.8 25.8
26/40
28.5 28.5 28.5 28.5 28.4 28.4 27.2 26.5