Interface Configuration
7210 SAS M, T, X, R6, R12, Mxp Interface Configuration Guide Page 19
Alcatel-Lucent SFPs and XFPs
The availability of the DDM real-time information and warning or alarm status is based on the
transceiver. It may or may not indicate if DDM is supported, although some Alcatel-Lucent SFPs
support DDM. Non-DDM and DDM-supported SFPs are distinguished by a specific ICS value.
For Alcatel-Lucent SFPs that do not indicate DDM support in the ICS value, DDM data is
available although the accuracy of the information has not been validated or verified.
For non-Alcatel-Lucent transceivers, DDM information may be displayed, but Alcatel-Lucent is
not responsible for formatting, accuracy, etc.
Statistics Collection
The DDM information and warnings/alarms are collected at one minute intervals, so the minimum
resolution for any DDM events when correlating with other system events is one minute.
Note that in the Transceiver Digital Diagnostic Monitoring section of the show port port-id detail
command output:
If the present measured value is higher than the either or both High Alarm, High Warn
thresholds; an exclamation mark “!” displays along with the threshold value.
If the present measured value is lower than the either or both Low Alarm, Low Warn
thresholds; an exclamation mark “!” displays along with the threshold value.
A:Dut-A# show port 2/1/6 detail
.........
===============================================================================
Transceiver Digital Diagnostic Monitoring (DDM), Internally Calibrated
===============================================================================
Value High Alarm High Warn Low Warn Low Alarm
-------------------------------------------------------------------------------
Temperature (C) +39.3 +96.0 +94.0 -7.0 -8.0
Supply Voltage (V) 3.27 3.51 3.49 3.12 3.10
Tx Bias Current (mA) 18.8 77.0 70.0 5.5 4.5
Tx Output Power (dBm) 1.33 5.50 5.00 0.00 -0.50
Rx Optical Power (avg dBm) -40.00 -8.50 -9.00 -33.98! -35.23!
===============================================================================

Table of Contents

Other manuals for Alcatel-Lucent 7210 SAS M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent 7210 SAS M and is the answer not in the manual?

Alcatel-Lucent 7210 SAS M Specifications

General IconGeneral
BrandAlcatel-Lucent
Model7210 SAS M
CategorySwitch
LanguageEnglish

Related product manuals