EasyManua.ls Logo

Alcatel-Lucent 7210 SAS M - Page 284

Alcatel-Lucent 7210 SAS M
347 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Interface Configuration
7210 SAS M, T, X, R6, R12, Mxp Interface Configuration Guide Page 279
Part Number : FTRJ8519P2BNL-A6
Optical Compliance : GIGE-SX
Link Length support: 550m for 50u MMF; 300m for 62.5u MMF
===============================================================================
Transceiver Digital Diagnostic Monitoring (DDM), Internally Calibrated
===============================================================================
Value High Alarm High Warn Low Warn Low Alarm
-------------------------------------------------------------------------------
Temperature (C) +26.2 +95.0 +90.0 -20.0 -25.0
Supply Voltage (V) 3.25 3.90 3.70 2.90 2.70
Tx Bias Current (mA) 1.0 17.0 14.0 2.0 1.0
Tx Output Power (dBm) -23.77 -2.00 -2.00 -11.02 -11.74
Rx Optical Power (avg dBm) -35.23 1.00 -1.00 -18.01 -20.00
===============================================================================
===============================================================================
Traffic Statistics
===============================================================================
Input Output
-------------------------------------------------------------------------------
Octets 128 640
Packets 2 10
Errors 0 0
===============================================================================
* indicates that the corresponding row element may have been truncated.
===============================================================================
Port Statistics
===============================================================================
Input Output
-------------------------------------------------------------------------------
Unicast Packets 2 10
Multicast Packets 0 0
Broadcast Packets 0 0
Discards 0 0
Unknown Proto Discards 0
===============================================================================
===============================================================================
Ethernet-like Medium Statistics
===============================================================================
Alignment Errors : 0 Sngl Collisions : 0
FCS Errors : 0 Mult Collisions : 0
SQE Test Errors : 0 Late Collisions : 0
CSE : 0 Excess Collisns : 0
Too long Frames : 0 Int MAC Tx Errs : 0
Symbol Errors : 0 Int MAC Rx Errs : 0
===============================================================================
*A:MTU-T1>show#
*A:MTU-T1>show# port 1/1/6 detail
===============================================================================
Ethernet Interface
===============================================================================

Table of Contents

Other manuals for Alcatel-Lucent 7210 SAS M

Related product manuals