Interface Configuration
7210 SAS M, T, X, R6, R12, Mxp Interface Configuration Guide Page 295
Admin State
up — the port is administratively up.
down — the port is administratively down.
Oper Duplex 
The operating duplex mode of the interface.
Oper State
up — the port is operationally up.
down — the port is operationally down.
Config Duplex 
full — the link is configured to full duplex mode.
half — the link is configured to half duplex mode.
Physical Link 
Yes — a physical link is present.
No — a physical link is not present.
MTU
The size of the largest packet that can be sent/received on the Ethernet 
physical interface, specified in octets.
IfIndex
The interface’s index number that reflects its initialization sequence.
Hold time up
The link-up dampening time in seconds. The port link dampening 
timer value that reduces the number of link transitions reported to 
upper layer protocols.
Last State Change
The last time that the operational status of the port changed state.
Hold time down
The link-down dampening time in seconds. The down timer controls 
the dampening timer for link down transitions.
Configured Mode 
network — the port is configured for transport. 
network use access — the port is configured for service access.
Encap Type
null — ingress frames will not use any tags or labels to delineate a ser-
vice.
dot1q — ingress frames carry 802.1Q tags where each tag signifies a 
different service.
Dot1Q Ethertype
The protocol carried in an Ethernet frame.
Net.Egr. Queue 
Pol.
The number of the associated network egress queue QoS policy, or 
default if the default policy is used.
Auto-negotiate
true — the link attempts to automatically negotiate the link speed and 
duplex parameters.
false — the duplex and speed values are used for the link.
Egress Rate 
The maximum amount of egress bandwidth (in kilobits per second) 
that this Ethernet interface can generate.
Loopback
The type of loopback configured on the port, either line,internal, or 
none.
Label Description  (Continued)