Interface Configuration
7210 SAS M, T, X, R6, R12, Mxp Interface Configuration Guide Page 327
Port Monitor Commands
port
Syntax port port-id [port-id...(up to 5 max)] [interval seconds] [repeat repeat] [absolute | rate]
[multiclass]
Context monitor
Description This command enables port traffic monitoring. The specified port(s) statistical information displays at the
configured interval until the configured count is reached.
The first screen displays the current statistics related to the specified port(s). The subsequent statistical
information listed for each interval is displayed as a delta to the previous display.
When the keyword rate is specified, the "rate per second" for each statistic is displayed instead of the delta.
Monitor commands are similar to show commands but only statistical information displays. Monitor
commands display the selected statistics according to the configured number of times at the interval
specified.
Parameters port port-idSpecify up to 5 port IDs.
Syntax: port-id slot/mda/port
interval seconds
Configures the interval for each display in seconds.
Default 10 seconds
Values 3 — 60
repeat repeatConfigures how many times the command is repeated.
Default 10
Values 1 — 999
absolute — When the absolute keyword is specified, the raw statistics are displayed, without processing.
No calculations are performed on the delta or rate statistics.
rate — When the rate keyword is specified, the rate-per-second for each statistic is displayed instead of the
delta.
Sample Output
A:ALA-12>monitor# port 1/4 interval 3 repeat 3 absolute
===============================================================================
Monitor statistics for Port 1/4
===============================================================================
Input Output
-------------------------------------------------------------------------------
At time t = 0 sec (Base Statistics)
-------------------------------------------------------------------------------

Table of Contents

Other manuals for Alcatel-Lucent 7210 SAS M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent 7210 SAS M and is the answer not in the manual?

Alcatel-Lucent 7210 SAS M Specifications

General IconGeneral
BrandAlcatel-Lucent
Model7210 SAS M
CategorySwitch
LanguageEnglish

Related product manuals