Card, Adapter Card, and Port Command Reference
Page 100 7705 SAR OS Interface Configuration Guide
threshold
Syntax threshold {ber-sd | ber-sf} rate threshold-rate
no threshold {ber-sd | ber-sf}
Context config>port>sonet-sdh
Description This command configures the line signal (b2) degradation bit error rate (BER) and line signal failure
thresholds.
Alarms are raised if the line signal bit interleaved parity error rates exceed either the degradation or
failure thresholds. If the failure threshold is crossed, the link will be set to operationally down.
The no form of this command reverts to the default value.
Default threshold ber-sf 6 —
signal degrade BER threshold of 10
-6
threshold ber-sf 3 — signal failure BER threshold of 10
-3
Parameters ber-sd — specifies the BER for signal degradation
ber-sf — specifies the BER for signal failure
rate threshold-ratespecifies the BER negative exponent (n in 10
-n
), expressed as a decimal
integer
Values 3 to 9 (10
-3
to 10
-9
)