7705 SAR Interfaces
7705 SAR OS Interface Configuration Guide Page 53
Configuring Adapter Card Fabric Profile
Use the following CLI syntax to assign a fabric profile on an adapter card.
CLI Syntax: config>card>mda#
mda-type {a16-chds1|a8-eth|a8-ethv2|a4-oc3}
[no] fabric-stats-enabled
network
ingress
fabric-policy <fabric-policy-id>
queue-policy <name>
access
ingress
fabric-policy <fabric-policy-id>
no shutdown
Configuring Ports
This section provides the CLI syntax and examples to configure the following:
Configuring Ethernet Port Parameters
Ethernet Network Port
Ethernet Access Port
Configuring Channelized Ports
Verifying the Adapter Card Type
Configuring SONET/SDH Port Parameters
SONET/SDH Access Port
Configuring ATM Interface Parameters
ATM Interface Commands
Configuring Multilink PPP Bundles
Configuring Multilink ATM Inverse Multiplexing (IMA) Groups
IMA Groups
Configuration Notes
IMA Test Procedure