Common Configuration Tasks
Page 52 7705 SAR OS Interface Configuration Guide
Use the config mda info command to display adapter card configuration information.
ALU-B>config>card>mda# info
----------------------------------------------
mda-type a16-chds1
network
ingress
queue-policy default
exit
exit
exit
----------------------------------------------
ALU-B>config>card>mda#
Configuring Adapter Card Clock Mode
Clocking mode is defined at the adapter card level. In Release 2.0 of the 7705 SAR, only the
T1/E1 ASAP Adapter card supports configuration of clocking mode and the only supported
clocking mode is adaptive.
Use the following CLI syntax to configure clocking mode on an adapter card.
CLI Syntax: config>card>mda#
clock-mode adaptive
no shutdown
Configuring Adapter Card Fabric Port Counters
Use the following syntax to configure fabric port counters on an adapter card.
CLI Syntax: config>card>mda#
[no] fabric-stats-enabled