Common Configuration Tasks
Page 58 7705 SAR OS Interface Configuration Guide
The following is an example of an E1 channel group configuration.
ALU-A>config>port>tdm# e1
ALU-A>config>port>tdm>e1# channel-group 1
ALU-A>config>port>tdm>e1>channel-group# timeslots 2
ALU-A>config>port>tdm>e1>channel-group# no shutdown
ALU-A>config>port>tdm>e1>channel-group#
ALU-A>config>port>tdm>e1# no shutdown
ALU-A>config>port>tdm>e1# channel-group 2
ALU-A>config>port>tdm>e1>channel-group# timeslots 3,4
ALU-A>config>port>tdm>e1>channel-group# encap-type cem
ALU-A>config>port>tdm>e1>channel-group# no shutdown
ALU-A>config>port>tdm>e1>channel-group# exit
----------------------------------------------
ALU-A>config>port>tdm#
Services can now be applied to the configured channelized ports.
Configuring SONET/SDH Port Parameters
Use the following CLI syntax to configure SONET/SDH port parameters.
CLI Syntax: [no] port {port-id}
sonet-sdh
clock-source {loop-timed | node-timed}
framing {sonet | sdh}
hold-time {[up hold-time-up] [down hold-time-
down]}
no hold-time
loopback {line | internal}
no loopback
[no] path [sonet-sdh-index]
atm
cell-format cell-format
min-vp-vpi value
crc {32}
description description
no description
encap-type {atm}
mtu mtu
no mtu
[no] report-alarm [pais] [plop] [prdi] [pplm]
[prei] [puneq]
[no] scramble
[no] shutdown
signal-label value
no signal-label
trace-string [trace-string]