Basic Configuration
Page 46 7705 SAR OS Interface Configuration Guide
Basic Configuration
The basic 7705 SAR OS interface configuration must include the following tasks:
• identify chassis slot (step in activating the IOM)
• specify card type (step in activating the IOM)
• identify adapter card (MDA) slot
• specify adapter card type (must be an allowed adapter card type)
• identify specific port to configure
The following example displays some card and port configurations.
ALU-A>config# info
. . .
#--------------------------------------------------
echo "Card Configuration"
#--------------------------------------------------
card 1
card-type iom-1g
mda 1
mda-type a4-oc3
no fabric-stats-enabled
network
ingress
fabric-policy 1
queue-policy "default"
exit
exit
access
ingress
fabric-policy 1
exit
exit
no shutdown
exit
mda 2
mda-type a4-oc3
no fabric-stats-enabled
network
ingress
fabric-policy 1
queue-policy "default"
exit
exit
access
ingress
fabric-policy 1
exit
exit
no shutdown
exit
mda 4
mda-type a16-chds1
clock-mode adaptive