Card, Adapter Card, and Port Command Reference
Page 120 7705 SAR OS Interface Configuration Guide
los — reports loss of signal errors. When configured, los traps are not raised and cleared.
Default los traps are issued
oof — reports out-of-frame errors. When configured, oof alarms are not raised and cleared.
Default oof alarms are not issued
rai — reports remote alarm indication signal errors. When configured, rai alarms are not raised and
cleared.
Default rai alarms are not issued
looped — reports looped packets errors
Default looped alarms are not issued
signal-mode
Syntax [no] signal-mode {cas}
Context config>port>tdm>ds1
config>port>tdm>e1
Description This command activates the signal mode on the channel. When enabled, control signals (such as those
for synchronizing and bounding frames) are carried in the same channels as voice and data signals.
Configure signal mode before configuring the Cpipe service to support T1 or E1 with CAS. Refer to
the 7705 SAR OS Services Guide for information on configuring Cpipe service.
This command is valid only when T1 framing is set to esf or sf, or E1 framing is set to g704 or no-
crc-g704.
Parameters cas — specifies channel associated signaling