EasyManua.ls Logo

Alcatel-Lucent 7705 - Notes

Alcatel-Lucent 7705
226 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7705 SAR Interfaces
7705 SAR OS Interface Configuration Guide Page 65
5. The test pattern procedure must be shut down before a new test-link value or test
pattern is accepted.
6. The current IMA group test pattern configuration and result of a given IMA test can
be seen by executing a show command for the IMA group. A test-link result can
have three values:
Disabled: the test-link is currently not running
Operating: the test pattern procedure is no shutdown and there are currently
no failed links for this running test-pattern procedure
Link-Failed: one or more links have failed the test-pattern procedure. Execute a
show port <slot/mda/port> ima-link command to see the failed
link and received pattern value.
7. Deleting a member link that is the same as the specified test-link, to stay in
compliance with key point 4, will result in the test-link value being reset to default.
8. IMA test procedure configurations are not saved when the admin save command is
executed.

Table of Contents