report-alarm
Syntax [no] report-alarm [loc] [lais] [lrdi] [lb2er-sd] [lb2er-sf] [slof] [slos] [lrei]
Context config>port>sonet-sdh
Description This command enables logging of SONET/SDH line and section alarms for a SONET/SDH port.
The no form of this command disables logging of the specified alarms.
Parameters loc — reports a loss of clock that causes the operational state of the port to be shut down
Default loss of clock alarms are issued
lais — reports line alarm indication signal errors. When configured, line alarm indication signal
alarms are raised and cleared.
Default line alarm indication signal alarms are not issued
lrdi — reports line remote defect indication errors. Line remote defect indication errors are caused by
remote loss of frame (LOF), loss of clock (LOC), and loss of signal (LOS) conditions. When
configured, line remote defect indication alarms are raised and cleared.
Default line remote defect indication alarms are issued
lb2er-sd — reports line signal degradation BER (bit interleaved parity) errors. When configured, line
signal degradation BER alarms are raised and cleared.
Default line signal degradation BER alarms are not issued
lb2er-sf — reports line signal failure BER errors. When configured, line signal failure BER alarms
are raised and cleared.
Default line signal failure BER alarms are issued
slof — reports section loss of frame errors. When configured, section loss of frame alarms are raised
and cleared.
Default section loss of frame alarms are issued
slos — reports a section loss of signal error on the transmit side. When configured, section loss of
signal alarms are raised and cleared.
Default section loss of signal alarms are issued
lrei — reports a line error condition raised by the remote end as a result of b1 errors received from
this node. When configured, line error traps are raised but not cleared.
Default line error traps are not issued