Interface Configuration
7750 SR Interface Configuration Guide Page 325
config>card>mda>network
config>port>access
Description This command enables the context to configure ingress buffer pool parameters which define the percentage
of the pool buffers that are used for CBS calculations and specify the slope policy that is configured in the
config>qos>slope-policy context.
On the MDA level, access ingress pools are only allocated on channelized MDAs/CMAs.
ingress-xpl
Syntax ingress-xpl
Context config>card>mda
Description This command enables the context to configure ingress MDA XPL interface error parameters.
threshold
Syntax threshold threshold
Context configure>card>mda>ingress-xpl
Description This command configures the Ingress XPL Error Threshold value used by the fail-on-error feature.
Parameters threshold — Specifies an upper limit on the frequency of Ingress XPL Errors that can occur on the MDA.
When fail-on-error is enabled, if the MDA experiences more than threshold errors per minute for win-
dow minutes, the MDA will be put in the failed state.
threshold cannot be changed while fail-on-error is enabled for this MDA.
Values 1 - 1000000
Default 1000
window
Syntax window window
Context configure>card>mda>ingress-xpl
Description This command configures the Error Window value used by the fail-on-error feature.
Parameters window — Specifies the time (in minutes) that the MDA can experience frequent Ingress XPL Errors. When
fail-on-error is enabled, if more than threshold Ingress XPL errors per minute occur on the MDA for
<window> consecutive minutes, the MDA will be put in the failed state.
window cannot be changed while fail-on-error is enabled for this MDA.