6 Software Procedures
6.4.4 Get telecom trace collect period/id (For CS, PS, ATRUNK only)
In this step of the script collects the necessary information for telecom trace
collection.
First, it will prompt the operator to input the telecom trace collection duration like
Please enter the duration time in seconds of telecom
trace collection [120]:
The duration will be collected as a number. Format check is needed.
Then, for CS/PS problem, 2 cell-ids are collected:
Enter the first LAC,CI [0,0]:
Enter the second LAC,CI [0,0]:
If operator only wants to input 1 cellid, press [ Enter ] for the second input.
For Atrunk problem, 2 Atrunk numbers are collected:
Enter first Atrunk Number [0]:
Enter second Atrunk Number [0]:
6.4.5 Send telecom trace config to TRF Master (For CS, PS, ATRUNK
only)
In this step of the script sends information for telecom trace collection to TRF
Master via MsgQ. The information includes the problem type, cellid/Atrunk
number and duration. It will reuse MSG 0150.
6.4.6 Wait enough time for telecom trace collection (For CS, PS, ATRUNK
only)
In this step of the script waits the duration time set for telecom trace collection
to be finished. For example, if operator input 120s as duration value, we need
to wait two mintues. During this time, it will print out following message
Wait 120 seconds for telecom trace collection. Press
B, if you want to stop it.
Waiting ..
One dot will be printed onto screen per second. If operator presses B at
this period, the script will send a ‘stop telecom trace collection’ command to
TRF Master. Either the time is finished or stopped by operator, the script
will go to next step.
After press B, for stop telecom trace collection, you must immediately click
[ Enter ] before the next dot appears.
6.4.7 Trigger all VCE to dump the remaining trace
In this step of the script sends a dump trace msg to TRF Master via MsgQ. It
will reuse MSG 0150.