Chassis and Power Supplies OmniSwitch 6860 Chassis Details
OmniSwitch 6860 Hardware Users Guide May 2014 page 3-7
OS6860-P24 Chassis Specifications
1
Fully populated weights include installed power supplies. These figures do not include transceivers.
2
Does not include attached PoE devices.
*Note On Chassis Versus Ambient Temperatures. Chassis temperature refers to the sensor reading of
the internal switch temperature (threshold or danger). Ambient temperature refers to the approximate room
temperature. The ambient temperature will typically be lower than the chassis temperature.
Chassis Height 4.4 cm (1.73 in)
Chassis Width 44 cm (17.33 in)
Chassis Depth 35 cm (13.78 in)
OS6860-P24 Chassis Weight 4.58 kg (10.1 lb)
OS6860-P24 Chassis Weight (fully populated)
1
6.03 kg (13.3 lb)
OS6860-P24 Power Consumption (full system power)
2
75 W
Altitude 13,000 ft
Operating Temperature (Tmra) 0°C to 45°C (32°F to 113°F)
Storage Temperature -40°C to 85°C (-40°F to 185°F)
Operating Humidity 5% to 95% non-condensing
Storage Humidity 5% to 95% non-condensing