READERHOST PROTOCOL CHAPTER 4
READER INTERFACE GUIDE
DOC. CONTROL # 8101938-000 REV 05
92
Autonomous Mode Kill
9800 | 9780 | 8780 | 9640 | 9774
In Autonomous Mode Kill, the reader can automatically kill a tag in its field, with a
specified PassCode. This event can be repeated indefinitely, each time with a
new tag.
To instruct Autonomous Mode to kill tags, issue the following command
set AutoAction = Kill
Instead of reading tags inside its inner loop (refer to AutoMode state diagram in
Chapter 2 for details), the reader kills a tag in its field with a PassCode, as
specified by the ProgramPassCode attribute (see above).
A successful Kill event causes the evaluation state of Autonomous Mode to
evaluate to
true. A failed Kill event evaluates to false.