CHAPTER 4 ALIEN READER PROTOCOL
READER INTERFACE GUIDE
DOC. CONTROL # 8101938-000 REV 05
37
ReaderNumber
9800 | 9780 | 8780 | 9640 | 9774
The reader can be assigned an arbitrary number to aid identification in multiple-
reader environments. This number can be retrieved and changed at any time
throughout reader operation.
Allowed values for ReaderNumber are 1-255.
The default ReaderNumber value is 255.
ReaderNumber Examples
Command
Response
>get ReaderNumber
ReaderNumber = 255
Command
Response
>set ReaderNumber = 15
ReaderNumber = 15
Uptime
9800 | 9780 | 8780 | 9640 | 9774
The Uptime command returns the elapsed time, in seconds, since the last time
the reader was rebooted.
Uptime Example
Command
Response
>get Uptime
Uptime (secs) = 702048
Username
9800 | 9780 | 8780 | 9640 | 9774
The reader can be operated over the network. When operated in this mode it
uses a simple username/password authentication scheme to stop unwelcome
visitors accessing it. This command allows the username to be defined and
obtained.
A username/password pair is not required when operating the reader via
serial connection.
The default username setting is “alienNOTE: The username is case
sensitive and must be entered in all lowercase.
Username Examples
Command
Response
>get Username
Username = alien
Command
Response
>set Username = hal
Username = hal
Password
9800 | 9780 | 8780 | 9640 | 9774
The reader can be operated over the network. When operated in this mode it
uses a simple username/password authentication scheme to stop unwelcome

Table of Contents