ALIEN READER PROTOCOL CHAPTER 4
READER INTERFACE GUIDE
DOC. CONTROL # 8101938-000 REV 05
40
RFAttenuation Examples
Command
Response
>get RFAttenuation
RFAttenuation = 0
Command
Response
>set RFAttenuation = 30
RFAttenuation = 30
FactorySettings
9800 | 9780 | 8780 | 9640 | 9774
The FactorySettings command will reset all reader settings to their factory default
values, and then reboot the reader. The reboot is required in order for the new
settings (especially network values) to take effect.
FactorySettings Examples
Command
Response
>FactorySettings
All settings have been reset !
Rebooting System...
Reboot
9800 | 9780 | 8780 | 9640 | 9774
The Reboot command causes the reader to immediately close all network
connections and reboot.
It is recommended that you reboot the reader any time network
configuration parameters are changed.
The ALR-9770 reader may also be rebooted via its web interface.
Browse to the reader’s IP address in a web browser, click the Restart link
on the left side of the page and follow the provided instructions.
Reboot Examples
Command
Response
>Reboot
Rebooting System...