Rockwell Automation Publication 1444-UM001D-EN-P - June 2018 185
Measurement Definition Chapter 4
HW Configuration
On the Hardware Configuration Page
, set the Measurement Type for both
channels of the pair to “Ramp Differential Expansion A/B” and the sensor
definitions are defaulted as shown in Figure 80
.
Figure 80 - Hardware Configuration Defaults
For each of the channels, edit the Xdcr attributes as appropriate to the sensor
input.