38 Rockwell Automation Publication KNX-RM009C-EN-P - May 2019
Kinetix 5500 Drive Systems
Performance specification data and curves reflect nominal system performance of a typical system with the motor at 40 °C (104 °F) and the drive at 50 °C (122 °F) ambient, and rated line voltage. For
additional information on ambient and line conditions, refer to Motion Analyzer software.
VPF-B0633T 8000 8000 3.52 1.27 (11.0)
8.80 2.87 (25.0)
0.48 (0.64)
2198-H008-ERSx
12.60 4.09 (36.0) 2198-H015-ERSx
VPF-B0752E 4900 4900 2.70 1.61 (14.0)
8.80 4.10 (36.0)
0.64 (0.86)
2198-H008-ERSx
9.45 4.39 (39.0) 2198-H015-ERSx
VPF-B0752F 7000 7000 3.80 1.61 (14.0) 13.30 4.39 (39.0) 0.76 (1.02) 2198-H015-ERSx
VPF-B0752M 8000 8000 4.90 1.61 (14.0)
17.70 4.10 (36.0)
0.77 (1.04)
2198-H015-ERSx
18.90 4.39 (39.0) 2198-H025-ERSx
VPF-B0753E 4500 4500 3.80 2.28 (20.0) 13.30 7.35 (65.0) 0.77 (1.04) 2198-H015-ERSx
VPF-B0753F 6600 6600 4.09 2.16 (19.0)
17.70 6.55 (58.0)
0.61 (0.82)
2198-H015-ERSx
18.90 7.02 (62.0) 2198-H025-ERSx
VPF-B0753M 8000 8000 6.12 2.28 (20.0)
17.70 5.13 (45.0)
0.78 (1.05)
2198-H015-ERSx
25.34 7.35 (65.0) 2198-H025-ERSx
VPF-B1001M 6000 6000 3.61 1.93 (17.0)
8.80 3.22 (28.0)
1.14 (1.53)
2198-H008-ERSx
10.38 3.78 (33.0) 2198-H015-ERSx
VPF-B1002E 3300 3300 3.44 3.39 (30.0)
8.80 6.47 (57.0)
1.12 (1.50)
2198-H008-ERSx
10.69 7.82 (69.0) 2198-H015-ERSx
VPF-B1002M 6000 6000 6.24 3.39 (30.0)
17.70 6.80 (60.0)
1.86 (2.49)
2198-H015-ERSx
20.33 7.82 (69.0) 2198-H025-ERSx
VPF-B1003C 2500 2500 3.41 4.18 (37.0)
8.80 9.29 (82.0)
0.91 (1.23)
2198-H008-ERSx
10.61 11.15 (99.0) 2198-H015-ERSx
VPF-B1003F 4750 4750 6.14 4.18 (37.0)
17.70 9.76 (86.0)
1.57 (2.10)
2198-H015-ERSx
20.20 11.15 (99.0) 2198-H025-ERSx
VPF-B1003T 7000 7000 9.58 4.18 (37.0)
28.30 9.76 (86.0)
1.68 (2.25)
2198-H025-ERSx
28.80 11.15 (99.0) 2198-H040-ERSx
VPF-B1153E 3200 3200 6.13 6.50 (58.0)
17.70 16.85 (149)
1.40 (1.88)
2198-H015-ERSx
21.33 20.33 (180) 2198-H025-ERSx
VPF-B1153F 5000 5000 8.88 6.50 (58.0)
28.30 18.30 (162)
1.49 (2.00)
2198-H025-ERSx
33.0 20.33 (180) 2198-H040-ERSx
VPF-B1303C 2250 2250 6.30 8.80 (78.0)
17.70 19.83 (175)
1.74 (2.33)
2198-H015-ERSx
18.47 20.72 (183) 2198-H025-ERSx
VPF-B1303F 4000 4000 10.10 8.80 (78.0)
28.30 19.85 (175)
2.54 (3.40)
2198-H025-ERSx
31.0 20.72 (183) 2198-H040-ERSx
VPF-B1304C 2150 2150 7.0 10.29 (91.0)
17.70 22.55 (199)
1.49 (2.00)
2198-H015-ERSx
22.3 28.45 (252) 2198-H025-ERSx
VPF-B1304E 3500 3500 9.44 10.29 (91.0)
28.30 25.03 (221)
2.40 (3.21)
2198-H025-ERSx
33.76 28.45 (252) 2198-H040-ERSx
VPF-B1652C 2700 2700 16.0 19.40 (172)
45.90 44.78 (396)
4.18 (5.60)
2198-H040-ERSx
49.88 48.60 (430) 2198-H070-ERSx
Bulletin VPF Motor Performance Specifications with Kinetix 5500 (400V-class operation) Drives (cont.)
Motor Cat. No.
Rated Speed
rpm
Speed, max
rpm
System Continuous
Stall Current
A (0-pk)
System Continuous
Stall Torque
N•m (lb•in)
System Peak
Stall Current
A 0-pk
System Peak
Stall Torque
N•m (lb•in)
Motor Rated
Output
kW (Hp)
Kinetix 5500 Drives
(480V AC input)