Page #83 background image
Rockwell Automation Publication KNX-RM009C-EN-P - May 2019 83
Kinetix 5500 Drive Systems
Performance Specifications with Frame 100 Linear Thrusters
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 40 °C (104 °F) ambient and rated line voltage. For additional
information on ambient and line conditions, refer to Motion Analyzer software.
Performance Specifications with Frame 150 Linear Thrusters
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 40 °C (104 °F) ambient and rated line voltage. For additional
information on ambient and line conditions, refer to Motion Analyzer software.
Linear Thruster
Cat. No.
Velocity, max
230V AC
m/s
System Continuous
Stall Current
Amps 0-pk
System Continuous
Stall Force
N (lb)
System Peak
Stall Current
Amps 0-pk
System Peak
Stall Force
N (lb)
Rated Output
230V AC
kW
Kinetix 5500 Drives
(240V AC input)
LDAT-S102010-DDx
LDAT-S102090-DDx
2.6 5.7
456 (103)
21.0
1289 (290)
0.96 2198-H025-ERSx
LDAT-S102010-EDx
LDAT-S102090-EDx
1.3 2.9 10.5 0.42 2198-H015-ERSx
LDAT-S103010-DDx
LDAT-S103090-DDx
2.7 8.6
702 (158)
31.5 1935 (435) 1.47 2198-H040-ERSx
LDAT-S103010-EDx
LDAT-S103090-EDx
0.9 2.9 10.5 1388 (312) 0.30 2198-H015-ERSx
LDAT-S104010-DDx
LDAT-S104090-DDx
2.7 11.5
929 (209)
42.0
2578 (580)
2.07 2198-H040-ERSx
LDAT-S104010-EDx
LDAT-S104090-EDx
1.3 5.7 21.0 0.86 2198-H025-ERSx
LDAT-S106010-DDx
LDAT-S106090-DDx
2.7 17.3
1403 (315)
63.0
3871 (870)
2.94 2198-H070-ERSx
LDAT-S106010-EDx
LDAT-S106090-EDx
1.3 8.6 31.5 1.28 2198-H040-ERSx
Linear Thruster
Cat. No.
Velocity, max
230V AC
m/s
System Continuous
Stall Current
Amps 0-pk
System Continuous
Stall Force
N (lb)
System Peak
Stall Current
Amps 0-pk
System Peak
Stall Force
N (lb)
Rated Output
230V AC
kW
Kinetix 5500 Drives
(240V AC input)
LDAT-S152010-DDx
LDAT-S152090-DDx
1.8 5.3
643 (145)
19.5 1799 (404) 0.87 2198-H025-ERSx
LDAT-S152010-EDx
LDAT-S152090-EDx
0.9 2.7 9.8 1679 (377) 0.34 2198-H015-ERSx
LDAT-S153010-DDx
LDAT-S153090-DDx
1.8 8.0 978 (220) 29.1 2680 (602) 1.33 2198-H040-ERSx
LDAT-S154010-DDx
LDAT-S154090-DDx
1.8 10.7
1306 (294)
39.1 3597 (809) 1.78 2198-H040-ERSx
LDAT-S154010-EDx
LDAT-S154090-EDx
0.9 5.3 19.5 3383 (761) 0.70 2198-H025-ERSx
LDAT-S156010-DDx
LDAT-S156090-DDx
1.8 16.3
1997 (449)
59.4 5469 (1229) 2.71 2198-H070-ERSx
LDAT-S156010-EDx
LDAT-S156090-EDx
0.9 8.1 19.8 5110 (1149) 1.05 2198-H025-ERSx

Other manuals for Allen-Bradley Kinetix 5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley Kinetix 5500 and is the answer not in the manual?

Allen-Bradley Kinetix 5500 Specifications

General IconGeneral
BrandAllen-Bradley
ModelKinetix 5500
CategoryServo Drives