82 Rockwell Automation Publication KNX-RM009C-EN-P - May 2019
Kinetix 5500 Drive Systems
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 40 °C (104 °F) ambient and rated line voltage. For additional
information on ambient and line conditions, refer to Motion Analyzer software.
Performance Specifications with Frame 70 Linear Thrusters
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 40 °C (104 °F) ambient and rated line voltage. For additional
information on ambient and line conditions, refer to Motion Analyzer software.
LDAT-S053010-DDx 4.1
9.4
378 (85)
34.2
1093 (246)
1.31
2198-H040-ERSx
LDAT-S053020-DDx 5.0 1.53
LDAT-S053030-DDx
…
LDAT-S053050-DDx
5.0 1.53
LDAT-S053010-EDx
…
LDAT-S053050-EDx
1.7 3.1 11.4 0.47 2198-H015-ERSx
LDAT-S054010-DDx 4.4
12.4
509 (114)
45.5
1453 (327)
1.87
2198-H040-ERSx
LDAT-S054020-DDx
…
LDAT-S054050-DDx
5.0 2.05
LDAT-S054010-EDx
…
LDAT-S054050-EDx
2.6 6.2 22.7 1.02 2198-H025-ERSx
Linear Thruster
Cat. No.
Velocity, max
230V AC
m/s
System Continuous
Stall Current
Amps 0-pk
System Continuous
Stall Force
N (lb)
System Peak
Stall Current
Amps 0-pk
System Peak
Stall Force
N (lb)
Rated Output
230V AC
kW
Kinetix 5500 Drives
(240V AC input)
LDAT-S072010-DDx
…
LDAT-S072070-DDx
3.5 6.0
364 (82)
22.0
1055 (237)
1.03 2198-H025-ERSx
LDAT-S072010-EDx
…
LDAT-S072070-EDx
1.7 3.0 11.0 0.47 2198-H015-ERSx
LDAT-S073010-DDx
…
LDAT-S073070-DDx
3.5 9.0
554 (125)
32.8
1576 (354)
1.57 2198-H040-ERSx
LDAT-S073010-EDx
…
LDAT-S073070-EDx
1.2 3.0 10.9 0.41 2198-H015-ERSx
LDAT-S074010-DDx
…
LDAT-S074070-DDx
3.5 11.9
730 (164)
43.5
2088 (469)
2.08 2198-H040-ERSx
LDAT-S074010-EDx
…
LDAT-S074070-EDx
1.8 6.0 21.7 0.95 2198-H025-ERSx
LDAT-S076010-DDx
…
LDAT-S076070-DDx
3.5 18.2
1122 (252)
66.4
3189 (717)
3.17 2198-H070-ERSx
LDAT-S076010-EDx
…
LDAT-S076070-EDx
1.8 9.1 33.2 1.45 2198-H040-ERSx
Performance Specifications with Frame 50 Linear Thruster (cont.)
Linear Thruster
Cat. No.
Velocity, max
230V AC
m/s
System Continuous
Stall Current
Amps 0-pk
System Continuous
Stall Force
N (lb)
System Peak
Stall Current
Amps 0-pk
System Peak
Stall Force
N (lb)
Rated Output
230V AC
kW
Kinetix 5500 Drives
(240V AC input)