EasyManua.ls Logo

Allen-Bradley Kinetix 5500 - Page 95

Allen-Bradley Kinetix 5500
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Rockwell Automation Publication KNX-RM009C-EN-P - May 2019 95
Kinetix 5500 Drive Systems
Kinetix 5500 (400V-class operation) Drives/LDAT-Series Integrated Linear Thruster Curves
2198-H015-ERSx and LDAT-S031040-DDx
Velocity (m/s)
Force
(N)
Force
(lb)
200
175
150
125
100
75
50
25
0
45.0
39.3
33.7
28.1
22.5
16.9
11.2
5.6
0
0
2
4
31
Peak curve represents
480V and 400V inputs
Velocity (m/s)
0
3
5
41
2
Force
(N)
Force
(lb)
2198-H025-ERSx and LDAT-S032040-DDx
2198-H015-ERSx and LDAT-S032040-EDx
400
350
300
250
200
150
100
50
0
89.9
78.7
67.4
56.2
45.0
33.7
22.5
11.2
0
Peak curve represents
480V and 400V inputs
2198-H040-ERSx and LDAT-S033040-DDx
Velocity (m/s)
Force
(N)
Force
(lb)
600
525
450
375
300
225
150
75
0
135
118
101
84.3
67.4
50.6
33.7
16.9
0
0
3
5
41
2
Peak curve represents
480V and 400V inputs
2198-H015-ERSx and LDAT-S033040-EDx
Velocity (m/s)
Force
(N)
Force
(lb)
600
525
450
375
300
225
150
75
0
135
118
101
84.3
67.4
50.6
33.7
16.9
0
0
3
5
41
2
Velocity (m/s)
0
3
5
41
2
Force
(N)
Force
(lb)
2198-H015-ERSx and LDAT-S051050-DDx
400
350
300
250
200
150
100
50
0
89.9
78.7
67.4
56.2
45.0
33.7
22.5
11.2
0
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC input voltage

Other manuals for Allen-Bradley Kinetix 5500