94 Rockwell Automation Publication KNX-RM009C-EN-P - May 2019
Kinetix 5500 Drive Systems
Performance Specifications with Frame 150 Linear Thrusters
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 40 °C (104 °F) ambient and rated line voltage. For additional
information on ambient and line conditions, refer to Motion Analyzer software.
Linear Thruster
Cat. No.
Velocity, max
460V AC
m/s
System Continuous
Stall Current
Amps 0-pk
System Continuous
Stall Force
N (lb)
System Peak
Stall Current
Amps 0-pk
System Peak
Stall Force
N (lb)
Rated Output
460V AC
kW
Kinetix 5500 Drives
(480V AC input)
LDAT-S152010-DDx 3.2
5.3
643 (145)
19.5
1799 (404)
1.76
2198-H025-ERSx
LDAT-S152020-DDx
…
LDAT-S152090-DDx
3.5 1.89
LDAT-S152010-EDx
…
LDAT-S152090-EDx
1.8 2.7 9.8 0.87 2198-H015-ERSx
LDAT-S153010-DDx
…
LDAT-S153090-DDx
3.6 8.0
978 (220)
29.1
2680 (602)
2.87 2198-H040-ERSx
LDAT-S153010-EDx
…
LDAT-S153090-EDx
1.2 2.7 9.1 0.80 2198-H015-ERSx
LDAT-S154010-DDx
…
LDAT-S154090-DDx
3.5 10.7
1306 (294)
39.1
3597 (809)
3.83 2198-H040-ERSx
LDAT-S154010-EDx
…
LDAT-S154090-EDx
1.8 5.3 19.5 1.78 2198-H025-ERSx
LDAT-S156010-DDx
…
LDAT-S156090-DDx
3.6 16.3
1997 (449)
59.4
5469 (1229)
5.85 2198-H070-ERSx
LDAT-S156010-EDx
…
LDAT-S156090-EDx
1.8 8.1 19.8 2.71 2198-H025-ERS
x