Pause Mode
Pressing the keypad with the door closed resumes the cycle.
Pressing the keypad terminates the cycle.
Power Failure Display Mode
The control enters this mode after a power failure while a cycle
was running. This informs the user that a cycle was interrupted
and did not complete normally. The display will show "Power
Failure" and "Press any key to exit".
Start Mode
The control displays different menus depending on user input
(keypad press, opening or closing the loading door, or IR commu-
nication). If there is no user input for 4.25 minutes, the control
dims the display's LCD backlight. The display lights when there
is user input.
In this mode, press the keypad to put the control in Run Mode
and save the hour and minute of the day the cycle was started.
Any cycle selection key or the Home key will change the display
to the Cycle Selection Menu. The Start key will start the selected
cycle or show the Close Door Menu. All other key presses are in-
valid.
Run Mode
Press the keypad once to enter Pause Mode. Press the key-
pad twice to stop the cycle. The control enters Run Mode during
a cycle. The display shows the Cycle Status Menu. The loading
door is closed during Run Mode. The control enters Door Open
Mode if the loading door opens.
End of Cycle Mode
The control enters this mode when a cycle is complete. The dis-
play shows "Cycle Complete" and time since completion, if Time
Since Completed Disp is enabled. The control enters Start Mode
when loading door is opened or a key is pressed.
System Check Mode
The front end control enters this mode after Power-Up Mode.
System Check Mode acts as an extension to Power-Up Mode and
during this mode, the control will check if the correct drive mo-
tor, fan motor and ignition control (for gas machines only) are
connected to the machine. If the motor type checks have success-
fully been completed or if the door is not closed prior to the five
(5) second timer expiring, the front end control will continue to
the next mode. The mode that is entered after System Check
Mode completes is determined in Power-Up Mode. If the door
was not closed and the motor type check was not completed, this
check will be done the next time the motor drive contactor is ena-
bled. If the test detects an incorrect drive motor, fan motor or ig-
nition control, a Board ID Error will be set
Factory Test Mode
The user can enter this mode via the keypad shortcut (if enabled,
refer to Globals Menu) or the Diagnostics Menu, network, or the
IrDA device from Start Mode.
While in Factory Test Mode the machine cycles through test steps
and displays. Refer to Factory Test Menu for more information.
Machine Error Mode
The control enters this mode when an error is set and displays all
alarms and machine errors.
Communication Mode
The control enters this mode while IR communication is in prog-
ress. The display shows the IR Communications Menu.
Manual Mode
Manual Mode allows the user to manually program, audit, and
access diagnostic functions rather than requiring the use of IR or
other communication source. When in Manual Mode, the control
displays the System Menu.
The owner can program the control (refer to Globals Menu) to re-
quire users to enter a passcode to access Manual Mode. The pass-
code can only be set with an external device or network.
Rapid Advance Mode
The user can enter Rapid Advance Mode via network or IR de-
vice from Start Mode or Run Mode.
If enabled (refer to Globals Menu), the user can access Manual
Rapid Advance (refer to Rapid Advance) via the keypad through
the System Menu.
When in Manual Rapid Advance, press the keypad to advance
to the next step for moisture dry or auto-dry cycles. For time dry
cycles, each press of the keypad will subtract one minute of
time. If keypad is pressed and held, time will decrement four
minutes per second.
Manual Diagnostic Mode
Manual Diagnostic Mode allows the user to manually access di-
agnostic functions rather than requiring the use of IR or other
communication source. When in Manual Diagnostic Mode, the
control displays the Diagnostics Menu.
Error Display Mode
If the control detects a machine error, it enters Error Display
Mode and displays the error. Only one (1) error displays at a time
if there are multiple errors. Once the highest priority error is
cleared, the control displays the next highest priority error if mul-
tiple errors exist. See Machine Errors for more details on error
descriptions, error displays and priorities.
Control Identification
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
18 Part No. 70549501ENR6