Alarms Menu
Figure 31
The Alarms Menu displays a list of the last 25 errors, starting
from the most recent, at the top of the screen. Below the list of
recent errors is a list of individual error audit counts showing the
type of error and how many times a specific error has occurred.
Inputs/Outputs Menu
Figure 32
The Inputs and Outputs Menu gives a user the ability to manipu-
late machine outputs and monitor the current state of all control
inputs. Refer to Table 10 for code definitions.
1. Press the arrow keypads to move the flashing output selector.
2.
Press the the keypad to select an output.
3. After selecting desired outputs, navigate to "Test" and press
the
keypad. "Test" changes to "Stop" and all currently se-
lected outputs change to the active state.
4.
Press the keypad again to terminate the currently running
test.
Inputs
ABP Network Board Present
AFS Air Flow Switch
AI Auxiliary Input
ALM Alarm
AP Access Panel
AX1 Spare Input
BBP USB/Reprogram Board
Present
CT Cabinet High Limit
DP1 DIP Switch 1
DP2 DIP Switch 2
DP3 DIP Switch 3
DP4 DIP Switch 4
DP5 DIP Switch 5
DP6 DIP Switch 6
DP7 DIP Switch 7
DP8 DIP Switch 8
DR Door
LDR Lint Door
MRL Manual Reset Limit
ST1 Stove 1 High Limit
ST2 Stove 2 High Limit
VLV ICM Valve (Gas Models Only)
Outputs
AP3 Inverter Motor Comm
AP4 Inverter Motor Comm
GV1 Gas Valve 1 (Gas Models On-
ly)
GV2 Gas Valve 2 (Gas Models On-
ly)
HT Heat
Table 10  continues...