EasyManua.ls Logo

Alliance Laundry Systems UTF75N - UniLinc Voltage and Configuration Tests

Alliance Laundry Systems UTF75N
65 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Test Name Display
Dryer On Temp Test Temperature: XXXF or XXXC
12.5VDC Voltage Test XX.XXV
24VDC Voltage Test XX.XXV
AC Mains Voltage Test XXX.X
Machine Config Test #1 XXX
Machine Config Test #2 XXX
Machine Config Test #3 XXX
Machine Config Test #4 XXX
Machine Config Test #5 XXX
ICM Alarm Status "Locked" or "Ready"
Heat Interlock Test "Air Flow Switch", "Cabinet Limit", "Stove Limit 1", "Stove
Limit 2", "Manual Reset Limit"
Fan Motor Test "Ready" or "Running"
Damper Motor Test "Ready" or "Running"
Motor Test "Ready" or "Running"
Moisture Test #1 "Time: 00:SS"
Moisture Test #2 "Time: 00:SS", "A2D: XXXX", Result: "READY", "PASS" or
"OPEN"
Diagnostic Test Descriptions
Dryer On Temp Test
This option tests the temperature inside the cylinder while run-
ning a cycle.
To enter, press the or keypads in the Individual Diagnostic
Tests Menu until Dryer On Temp Test is highlighted and then
press the keypad. The machine will run until it has reached the
selected cycle temperature. The display will show "XXXF" for
degrees in Fahrenheit or "XXXC" for degrees in Celsius. The
XXX will show the degrees.
To exit the test, press the keypad. keypad will exit all tests.
12.5VDC Voltage Test
This test displays the value of the 12.5VDC supply.
To enter, press the or keypads in the Individual Diagnostic
Tests Menu until 12.5VDC Voltage Test is highlighted and then
press the keypad. The display will show "XX.XXV" where
"XX.XXV" is the value of the 12.5VDC supply. "V" is volts.
To exit the test, press the
keypad. keypad will exit all tests.
24VDC Voltage Test
This test displays the value of the 24VDC supply.
To enter, press the or keypads in the Individual Diagnostic
Tests Menu until 24VDC Voltage Test is highlighted and then
press the keypad. The display will show "XX.XXV" where
"XX.XXV" is the value of the 24VDC supply. "V" is volts.
To exit the test, press the keypad. keypad will exit all tests.
AC Mains Voltage Test
This test displays the value of the curent AC Mains Voltage.
To enter, press the or keypads in the Individual Diagnostic
Tests Menu until AC Mains Voltage Test is highlighted and then
press the keypad. The display will show "XXX.X" where
"XXX.x" is the current AC mains voltage.
To exit the test, press the keypad. keypad will exit all tests.
Machine Config Test #1
This option shows whether communication interfaces are con-
nected.
To enter, press the or keypads in the Individual Diagnostic
Tests Menu until Machine Config Test #1 is highlighted and then
Diagnostics Menu
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
45 Part No. 70549501ENR6