Anti-Wrinkle Mode
The cycle will enter Anti-Wrinkle Mode two (2) minutes after the
cycle has ended. The display will show "Anti-Wrinkle". Upon en-
tering Anti-Wrinkle Mode, the control will increment the Total
Number of Extended Tumble Cycles audit counter. The control
will continue to show the End of Cycle Mode display. During the
Anti-Wrinkle portion, the control, if enabled will sound an audio
warning prior to turning on the motor for 30 seconds every two
(2) minutes.
The dryer will remain in this mode for up to 1 hour, or until the
door is opened, a key is pressed or a start pulse is received. When
the Anti-Wrinkle Mode timer expires the control increments the
Anti-Wrinkle Exceeded audit counter and enters Extended Tum-
ble Mode. If the door is opened, a key is pressed or a start pulse
is received before Anti-Wrinkle Mode expires, the control will
enter Ready Mode. Anti-Wrinkle Mode is not included in the To-
tal Operating Minutes counter.
The dryer will remain in this mode for up to 1 hour, or until the
door is opened, a key is pressed. When the Anti-Wrinkle Mode
timer expires the control increments the Anti-Wrinkle Exceeded
audit counter and enters Extended Tumble Mode. If the door is
opened or a key is pressed before Anti-Wrinkle Mode expires, the
control will enter Start Mode. Anti-Wrinkle Mode is not included
in the Total Operating Minutes counter.
Extended Tumble Mode
Extended Tumble Mode is entered after Anti-Wrinkle Mode has
finished. The display will show "Extended Tumble". During the
Extended Tumble, the control will turn on the motor for 2 mi-
nutes every 1 hour. If the extended tumble audio option is ena-
bled, the control will beep for five seconds and then stay solid for
five seconds prior to turning on the motor.
The control will remain in this mode for up to 18 hours, or until
the door is opened, a key is pressed or a start pulse is received.
When the Extended Tumble timer expires the control will remain
in Extended Tumble Mode. If the door is opened, a key is pressed
or a start pulse is received before Extended Tumble Mode ex-
pires, the control will enter Ready Mode or Start Mode. Extended
Tumble Mode is not included in the Total Operating Minutes
counter.
The control will remain in this mode for up to 18 hours, or until
the door is opened or a key is pressed. When the Extended Tum-
ble timer expires the control will remain in Extended Tumble
Mode. If the door is opened or a key is pressed before Extended
Tumble Mode expires, the control will enter Start Mode. Extend-
ed Tumble Mode is not included in the Total Operating Minutes
counter.
WARNING
Disabling this feature may lead to overheating of
clothes, which may lead to spontaneous combustion
and fire. By disabling this feature, you hereby re-
lease and hold harmless Alliance Laundry Systems
LLC of any damages caused by fire, including but
not limited to, property damage, personal injury or
death, and agree to indemnity Alliance Laundry Sys-
tems LLC from in any proceeding or cause of action
related to such action.
W960
Control Identification
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
19 Part No. 70549501ENR6