Display Description Cause/ Corrective Action
Shorted Output Error (2) Motor Relay Enable Output Shorted Check motor power relay connected be-
tween, if error persists replace relay.
Shorted Output Error (3) Spare Relay Enable Ouptut Shorted Check relay powered by KM2 output, if
error persists replace relay.
Shorted Output Error (4) Auxiliary Relay 1 Ouput Shorted Error Check relay powered by Aux 1 output, if
error persists replace relay.
Shorted Output Error (5) Run Relay Output Shorted Error Check Relay powered by the Run output,
if error persists replace relay.
Shorted Output Error (6) Gas Valve 1 Output Shorted Error Check gas valve 1, if error persists replace
valve.
Shorted Output Error (7) Gas Valve 2 Output Shorted Error Check gas valve 2, if error persists replace
valve.
ICM Error (2) ICM Alarm Reset Shorted Error Check wiring between the I/O board and
the ignition control. Power down and pow-
er up machine to clear the error.
ICM Error (3) ICM Hardware Failure Error Ignition control has detected a hardware
fault. Power down and power machine to
clear error. Replace ignition control if error
persists.
ICM Error (4) ICM Lockout Alarm Active Check that the gas is turned on and that the
ignition circuit functions. Also check that
the gas valve is operational. This error
needs to be manually reset. To reset, open
service door and press start button. After 5
seconds error should be cleared.
Output Board Error (5) I/O Board 24VDC Supply Over Voltage
Error
Check machine input voltage. Power down
and power up the machine to clear error. If
error persists, replace I/O board.
Output Board Error (6) I/O Board 24VDC Supply Under Voltage
Error
Check machine input voltage. Check for
pinched control wires. Clear any debris or
lint from the I/O board. Power down and
power up the machine to clear error. If er-
ror persists, replace I/O board.
Output Board Error (7) Heat Output Shorted Error Power down machine to clear error, power
up machine, try heating again. If error per-
sists, replace I/O board.
Output Board Error (32) Mosfet Enabled Shorted Error Power down machine to clear error, power
up machine, try running a cycle. If error
persists, replace I/O board.
Table 17
Machine Errors
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
57 Part No. 70549501ENR6