The wire colors will be the same regardless of control type.
Splice the after-market central pay system wires to the tumble
dryer control wire harness as follows.
Wire Colors Description
Red Start Pulse Signal Input
Black Start Pulse Signal Input
White with Red Stripe "Machine Available" Signal
Output
Orange with Black Stripe "Machine Available" Signal
Output
Start Pulse Requirements
All control types will consider a pulse valid if it is between 10
and 1000 milliseconds in length, with a minimum of 25 millisec-
onds between pulses.
Grounding Instructions
NOTE: To ensure protection against shock, this ma-
chine MUST be electrically grounded in accordance
with the local codes, or in the absence of local codes,
with the latest edition of the National Electrical Code
ANSI/NFPA No. 70. In Canada the electrical connec-
tions are to be made in accordance with CSA C22.1 lat-
est edition Canadian Electrical Code, or local codes.
Electrical work should be done by a qualified electri-
cian.
This machine must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock by
providing a path of least resistance for electric current. This ma-
chine must be connected to a grounded metal, permanent wiring
system; or an equipment grounding conductor must be run with
the circuit conductors and connected to the appropriate ground
location.
• Metal conduit and/or BX cable is not considered ground.
• Connecting the Neutral from the electrical service box to the
tumble dryer ground screw does not constitute a ground.
• A dedicated ground conduit (wire) must be connected be-
tween the electrical service box ground bar and machine
ground screw.
WARNING
To reduce the risk of electrical shock, de-energize
the electrical circuit being connected to the tumble
dryer before making any electrical connections. All
electrical connections should be made by a qualified
electrician. Never attempt to connect a live circuit.
W409R1
CAUTION
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dan-
gerous operation. Verify proper operation after serv-
icing.
W071
For On Premises Laundry (OPL) Models Only
IEC OPL (non-vend) models are factory-equipped with an emer-
gency stop button on the front panel.
NOTE: Activation of the emergency stop switch stops
all tumble dryer control circuit functions, but DOES
NOT remove all electrical power from tumble dryer.
Service/Ground Location
Model Heat Source Ground and Terminal Block Locations
030
035
055 (gas only)
Gas/steam, low voltage
Gas/steam, high voltage
1. Ground
2. Power Distribution Block
Table continues...
Electrical Requirements
©
Published by permission of the copyright owner -
DO NOT COPY or TRANSMIT
66 Part No. 70686701ENR4